Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 999
Filter
1.
Journal of Peking University(Health Sciences) ; (6): 108-113, 2023.
Article in Chinese | WPRIM | ID: wpr-971281

ABSTRACT

OBJECTIVE@#To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.@*METHODS@#Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.@*RESULTS@#The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).@*CONCLUSION@#The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.


Subject(s)
Humans , Tooth Preparation, Prosthodontic/methods , Incisor , Learning Curve , Crowns , Tooth Preparation , Ceramics , Dental Porcelain , Dental Prosthesis Design
2.
Journal of Peking University(Health Sciences) ; (6): 94-100, 2023.
Article in Chinese | WPRIM | ID: wpr-971279

ABSTRACT

OBJECTIVE@#To study microstructure, friction and wear behaviors of silicon-lithium spray coating on the surface of zirconia ceramics and to preliminarily evaluate its esthetic so as to provide support and guidance for the clinical application.@*METHODS@#Zirconia ceramic specimens were randomly divided into three groups: coating group (two subgroups), polishing group (two subgroups), and glazing group (four subgroups), with 10 samples in each subgroup. The two subgroups of coating group were the zirconia ceramics with the untreated and preliminary polishing surfaces sprayed with silicon-lithium coating, respectively. The two subgroups of polishing group were preliminary polishing and fine polishing of zirconia ceramics, respectively. The four subgroups of glazing group were preliminarily polished zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively; and untreated zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively. The above 8 subgroups of zirconia ceramic specimens were used as friction pairs with 80 steatite ceramics for 50 000 chewing cycles under 50 N vertical load and artificial saliva lubrication using chewing simulation. Scanning electron microscope was used to observe the microstructure of the surface and section of the coating group, and the thickness of the coating and glazing were measured. The linear roughness of the coating and polishing groups was mea-sured using a laser confocal scanning microscope. Vickers hardness was measured using a microhardness tester and the esthetic of zirconia ceramic full crown sprayed with silicon-lithium coating was preliminarily evaluated. White light interferometer was used to measure the width, the maximum depth and the volume of the wear scars of each group, and the wear depth of steatite ceramics and wear rate of zirconia ceramic specimens were calculated. Kruskal-Wallis nonparametric test and Dunn's multiple comparisons test were used to analyze the wear depth of each group (α=0.05).@*RESULTS@#The microstructures of the silica-lithium spray coatings on the untreated and preliminarily polished zirconia ceramic surfaces showed the protruding defects, and the line roughness of coating group was larger than that of the polishing group. The median thickness of the silica-lithium spray coating on the preliminarily polished zirconia ceramic was 13.0 μm (interquartile range, IQR: 11.6, 17.9), while that of the silica-lithium spray coating on the untreated zirconia ceramic was 4.4 μm (IQR: 4.1, 4.7). The Vickers hardness and wear rate of the coating group were between the polishing group and the glazing group. The wear depths of the wear scars of steatite ceramics were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference between glazing and polishing groups (P < 0.05). With the increase of polishing procedure, the wear depth of steatite ceramics decreased in each subgroups. The orders of maximum depth and volume of wear scars of zirconia ceramic were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference in the maximum depth of wear scars between glazing and polishing groups (P < 0.05).@*CONCLUSION@#The silica-lithium spray coating on the zirconia ceramic, can be used as a new method for zirconia ceramic surface treatment, because it can increase the esthetic of zirconia ceramics compared with polishing and reduce the wear of steatite ceramics compared with glazing.


Subject(s)
Humans , Silicon , Materials Testing , Friction , Lithium , Cicatrix , Surface Properties , Silicon Dioxide , Zirconium/chemistry , Ceramics , Dental Porcelain
3.
Braz. j. oral sci ; 22: e231377, Jan.-Dec. 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1519248

ABSTRACT

The aim of this study was to investigate the influence of the quantity and positioning of feldspathic ceramic specimens inside the furnace on their flexural strength and translucency. The tested hypotheses were that the arrangement of specimens in the furnance would not influence 1) the translucency or 2) the biaxial strength of the porcelain. Methods: Ninety porcelain specimens were made (1.2 mm thickness and 13.5 mm diameter) and assigned into two main groups (n=15): G1 group - 15 firing cycles containing only one specimen each, always at the center of the refractory; and G5 group - 15 firing cycles containing five specimen each, where one specimen was at the center of the refractory and four specimens positioned equidistantly on the periphery. The translucency test was performed using a spectrophotometer, followed by the flexural strength test, according to ISO 6872:2015. T-student test was performed for both the mechanical and optical obtained data. Results: The flexural strength of the porcelain was not affected by the positioning (center x periphery) of the specimens inside the furnace (p =0.08), but the translucency was affected (periphery > center; p =0.009). Regarding to the number of feldspathic ceramic specimens, the biaxial flexural strength was affected (p =0.025), as well as the translucency (p <0.05). Conclusion: A higher quantity of feldspathic ceramic specimens for each firing cycle decreased its biaxial flexural strength and translucency. Also, specimens positioned at the center of the refractory became less translucent than those positioned at the periphery.


Subject(s)
Humans , Thermodynamics , Dental Porcelain/chemistry , Absorption, Physicochemical , Flexural Strength , Light , Spectrophotometry , Temperature , Materials Testing , Microscopy, Electron, Scanning , Fractographic Analysis
4.
Braz. dent. sci ; 26(3): 1-12, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1511733

ABSTRACT

Objective:This study evaluated the effect of immediate dentin sealing on the marginal adaptation of lithium disilicate overlays with three different types of resin-luting agents: preheated composite, dual-cure adhesive resin, and flowable composite. Materials and Methods: Forty-eight maxillary first premolars of similar size were prepared with a butt joint preparation design. The teeth were separated into two primary groups, each with twenty-four teeth: Group DDS: Delay dentin sealing (non-IDS) teeth were not treated. Group IDS: dentin sealing was applied immediately after teeth preparation. Each group was subsequently separated into three separate subgroups. Subgroups (DDS+Phc, IDS+Phc): cemented with preheated composite (Enamel plus HRi, Micerium, Italy), Subgroups (DDS+Dcrs, IDS+Dcrs): cemented with dual-cured resin cement (RelyX Ultimate, 3M ESPE, Germany) and Subgroups (DDS+Fc, IDS+Fc): Cemented with flowable composite (Filtek supreme flowable, 3M ESPE, USA). Using a digital microscope with a magnification of 230x, the marginal gap was measured before and after cementation at four different locations from each surface of the tooth, and the mean of measurements was calculated and analyzed statistically using the independent t-test, one-way ANOVA test, Bonferroni correction at a significance level of 0.05. Results: The samples that were immediately sealed with dentin bonding agent showed lower marginal gaps than delayed dentin sealing, both pre-and post-cementation for all subgroups, with a statistically significant difference (p˂0.01). The marginal gap was significantly lower in the IDS+Fc (48.888 ±5.5 µm) followed by the IDS+Dcrs group (53.612 ±5.8 µm) and IDS+Phc (79.19 9±6.9 µm) respectively, while the largest marginal gaps were observed in the DDS+Phc group (86.505 ±5.4 µm). Conclusion: Generally, the teeth with IDS showed better marginal adaptation than teeth without IDS. The marginal gap was smaller with flowable composite and dual-cure resin cement than with preheated composite (AU)


Objetivo:Esse estudo avaliou o efeito do selamento imediato da dentina na adaptação marginal de overlays em dissilicato de lítio com três tipos diferentes de agentes de cimentação resinosos: resina composta pré-aquecida, adesivo resinoso dual e resina fluida. Materiais e métodos: Quarenta e oito primeiros pré-molares maxilares com tamanho similar foram preparados com término em ombro. O dente foi separado em dois grupos primários, cada um com vinte e quatro dentes: Grupo DDS: retardado selamento da dentina (non-IDS) dente não foi tratado. Grupo IDS: selamento dentinário foi aplicado imediatamente após a preparação do dente. Cada grupo foi separado de modo subsequente em três subgrupos. Subgrupo (DDS+Phc, IDS+Phc): cimentado com resina pré-aquecida (Enamel plus HRi, Micerium, Italy), Subgrupo (DDS+Dcrs, IDS+Dcrs): cimentado com cimento resinoso dual (RelyX Ultimate, 3M ESPE, Germany) e Subgrupo (DDS+Fc, IDS+Fc): cimentado com resina fluida (Filtek supreme flowable, 3M ESPE, USA). Usando um microscópio digital com magnificação de 230x, o gap marginal foi medido antes e após a cimentação em quatro diferentes localizações de cada superfície do dente e a média das medidas foi calculada e estatisticamente analisada através do uso do teste ANOVA um-fator e teste independente de Tukey e correção Bonferroni com nível de significância de 0,05. Resultado: As amostras que foram imediatamente seladas com agente adesivo dentinário apresentaram menores gaps marginais do que o selamento dentinário retardado, ambos pré e pós cimentação para todos os subgrupos apresentaram diferença estatística significante (p˂0.01). O gap marginal foi significativamente menor para IDS+Fc (48.888 ±5.5 µm) acompanhado do IDS+Dcrs group (53.612 ±5.8 µm) e IDS+Phc (79.19 9 ±6.9 µm) respectividamente, enquanto o maior gap marginal foi observado no grupo DDS+Phc (86.505 ±5.4 µm). Conclusão:Geralmente, o dente com IDS apresentou melhor adaptação marginal do que o dente sem IDS. O gap marginal foi menor com resina fluida e cimento resinoso dual do que com a resina composta pré-aquecida (AU)


Subject(s)
Cementation , Computer-Aided Design , Dental Marginal Adaptation , Resin Cements , Dental Porcelain
5.
Araçatuba; s.n; 2022. 54 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1435699

ABSTRACT

O objetivo desse trabalho foi avaliar a influência de diferentes graus de opacidade e espessuras do dissilicato de lítio no grau de conversão de dois cimentos resinosos e na resistência de união dos mesmos à cerâmica. Duzentos e quarenta amostras cerâmicas de dissilicato de lítio (6x6 mm) foram obtidos a partir de blocos de IPS E-max CAD (Ivoclar Vivadent, Schaan, Liechtensten), nas opacidades HT (alta translucidez), LT (baixa translucidez) e MO (média opacidade), nas espessuras de 0,3 mm, 0,7 mm, 1,2mm, 1,7 mm, 2,0 mm. Para as análises do grau de conversão (n=9) e resistência de união (n=8) foram utilizados um cimento de ativação física (Variolink Esthetic LC) e um cimento dual (Multilink N). Para análise do grau de conversão, as amostras de cimento foram fotoativadas sob as amostras de cerâmica e levadas a um espectrômetro Raman confocal. Para o teste de resistência de união foram confeccionados cilindros de cimento resinoso sobre as amostras cerâmicas e submetidos ao ensaio de microcisalhamento. Os resultados mostraram que o aumento das espessuras causou diminuição no grau de conversão dos dois cimentos em todas as condições estudadas, porém só influenciou negativamente a resistência de união do cimento Variolink Esthetic LC quando unido à cerâmica na opacidade MO. Na comparação entre as opacidades, de maneira geral, a cerâmica de maior translucidez HT apresentou maiores valores de grau de conversão em comparação às outras opacidades. Já para resistência de união, em algumas espessuras as cerâmicas LT e MO apresentaram os maiores valores. O cimento dual Multilink N apresentou os maiores valores nas duas análises comparado ao cimento fotoativado Variolink Esthetic LC. Portanto, o aumento da espessura e da opacidade do material cerâmico podem promover uma diminuição no grau de conversão do cimento. A resistência de união também sofre uma diminuição com o aumento da espessura de cerâmicas mais opacas. No entanto, a maior translucidez do material não garante valores mais altos dessa mesma propriedade(AU)


This research aims to evaluate the influence of different degrees of opacity and thicknesses of lithium disilicate on the degree of conversion of two resin cements and on their bond strength to the ceramic. Two hundred and forty lithium disilicate ceramic samples (6x6 mm) were obtained from IPS E-max CAD (Ivoclar Vivadent, Schaan, Liechtensten), in HT, LT and MO opacities, with thicknesses of 0.3 mm, 0.7 mm, 1.2 mm, 1.7 mm, 2.0 mm. For degree of conversion (n=9) and bond strength analysis (n=8) a light cured (Variolink Esthetic LC) and a dual cured resin cement (Multilink N) were used. To analyze the degree of conversion, the cement samples were light cured under the ceramic samples and taken to a confocal Raman spectrometer. For the bond strength test, resin cement cylinders were made on the ceramic samples that were later subjected to a microshear. The results showed that the increase in thickness caused a decrease on degree of conversion of both cements in all the conditions studied, but it only had an influence on bond strength of Variolink LC cement for MO ceramic. Comparing the opacities, for the degree of conversion, the most translucent ceramics had higher conversion values compared to the less translucent ones in some thicknesses. As for bond strength, in some thicknesses the LT and MO ceramics showed the highest values. The dual cement Multilink showed the highest values of conversion degree and bond strength compared to Variolink Esthetic LC light-cured cement. The Multilink dual cement showed the highest values in both analyzes compared to the Variolink LC light-cured cement. Therefore, increasing the thickness and opacity of the ceramic material can promote a decrease in the degree of cement conversion. The bond strength also suffers a decrease with increasing thickness of more opaque ceramics and the greater translucency of the material does not guarantee higher values of this same property(AU)


Subject(s)
Resin Cements , Dental Porcelain , Ceramics , Dental Materials , Polymerization
6.
Pesqui. bras. odontopediatria clín. integr ; 22: e210044, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1365224

ABSTRACT

ABSTRACT Objective To assess the effects of coloring beverages on the color stability of two types of hybrid ceramics with different surface treatments. Material and Methods 180 specimens of two hybrid ceramics (Vita Enamic and Mazic Duro) and a feldspathic ceramic (Vita Mark II) were prepared (n=60 in each group). Half of the discs in each group were glazed while the other was polished. The specimens were then divided into three subgroups and immersed in distilled water, carrot juice, and coffee. The overall color difference (∆E) was calculated based on CIE L*a*b* color space. Data were analyzed using three-way and one-way ANOVA; Tukey's honest significant difference was also done for pairwise comparisons (α=0.05). Results Vita Mark II specimens revealed less overall color changes compared to other groups. The ∆E of the glazed Vita Enamic specimens was greater than polished specimens following immersion in distilled water (p=0.03) and coffee (p=0.001), but it was not significant for carrot juice. The same results were obtained for polished Mazic Duro specimens. Relatively similar amounts of ∆E were recorded in polished and glazed subgroups of Vita Mark II. Conclusion The ∆E of hybrid ceramics was higher than Vita Mark II. Polishing could be recommended for surface treatment of hybrid ceramics instead of glazing, saving time and facilitating the process.


Subject(s)
Spectrophotometry/instrumentation , Surface Properties , Beverages , Color , Dental Cements , Distilled Water , Ceramics , Analysis of Variance , Dental Prosthesis , Computer-Aided Design/instrumentation , Coffee , Dental Porcelain , Coloring Agents , Fruit and Vegetable Juices , Iran/epidemiology
7.
Article in English | LILACS, BBO | ID: biblio-1365234

ABSTRACT

ABSTRACT Objective To evaluate the marginal adaptation of computer-aided designing and computer-aided machining (CAD/CAM) fabricated cobalt-chromium and zirconium-oxide-based ceramic crowns compared to those produced by a conventional method. Material and Methods The study consists of three groups; 45 crowns fabricated from cobalt-chromium (CAD-CoCr) and 45 crowns manufactured from zirconium CAD/CAM technology (CAD-Z), and 45 control (C) which consists of conventional metal-ceramic crowns. The marginal discrepancies in vertical dimensions were assessed utilizing a microscope in four surfaces (mesial, distal, vestibular, and oral) for each crown. On completion of the microscopic evaluation, multivariate analysis of variance (MANOVA) was used to study the difference in the four surfaces, considered altogether. Two-way ANOVA revealed the effect of three systems used for gap measurements of each landmark. The differences observed were considered significant at p<0.05. Results There were no differences in the four surfaces revealed by АNOVА in the three groups when considered altogether. Two-way ANOVA of each surface discovered no differences among all groups as well. Conclusion The CAD/CAM crowns revealed a comparable and satisfactory marginal adaptation compared to conventional metal-ceramic crowns.


Subject(s)
Zirconium , Chromium Alloys , Dental Prosthesis/instrumentation , Crowns , Dental Porcelain , In Vitro Techniques , Analysis of Variance , Metal Ceramic Alloys , Computer-Aided Design , Dental Marginal Adaptation , India
8.
Article in English | LILACS, BBO | ID: biblio-1422288

ABSTRACT

Abstract Objective: To compare porcelain and metal repair done with both nanocomposite and conventional composite. Material and Methods: A total of 30 cylinders were fabricated from Porcelain (I), Porcelain fused to metal (II), and metal (III) substrate each. Control group (A) was bonded with conventional micro-hybrid composite and experimental group (B) was bonded with nanocomposite in a 2 mm thickness. All specimens were thermocycled and stored in distilled water at 37 °C for 7 days. A universal testing machine was used to measure the Shear bond strength (SBS). The difference between bond strengths of the groups was compared using an independent t-test. Results: In all three groups, the SBS was higher in the experimental group as compared to the control group. The use of nanocomposite of metal alloy presented maximum shear bond strength, followed by samples of porcelain fused to metal and finally porcelain, showing the lowest values of SBS. Conclusion: Porcelain and alloys bonded with nanocomposite exhibit enhanced adhesiveness as well as aesthetic and mechanical properties. This subsequently would translate into providing higher clinical serviceability and durability and hence a cost-effective and accessible repair option for human welfare (AU).


Subject(s)
Shear Strength , Dental Porcelain , Nanostructures/chemistry , Nanocomposites/chemistry , Analysis of Variance , Dental Alloys
9.
Journal of Peking University(Health Sciences) ; (6): 140-145, 2022.
Article in Chinese | WPRIM | ID: wpr-936125

ABSTRACT

OBJECTIVE@#To analyze the marginal roughness and marginal fitness of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) laminate veneers with different materials and thicknesses, and to provide a reference for the clinical application of laminate veneers.@*METHODS@#The butt-to-butt type laminate veneers were prepared on resin typodonts, the preparations were scanned, and the laminate veneers were manufactured by chairside CAD/CAM equipment. The laminate veneers were divided into four groups (n=9) according to the materials (glass-matrix ceramics and resin-matrix ceramics) and thickness (0.3 mm and 0.5 mm) of the veneers, with a total of 36. The marginal topo-graphies of each laminate veneer were digitally recorded by stereomicroscope, and the marginal rough-nesses of the laminate veneers were determined by ImageJ software. The marginal fitness of the laminate veneers was measured by a fit checker and digital scanning and measuring method. At the same time, the mechanical properties of glass-matrix ceramic and resin-matrix ceramic bars (n=20) were tested by a universal testing device.@*RESULTS@#The marginal roughness of 0.3 mm and 0.5 mm glass-matrix ceramic laminate veneers was (24.48±5.55) μm and (19.06±5.75) μm, respectively, with a statistically significant difference (P < 0.001). The marginal roughness of 0.3 mm and 0.5 mm resin-matrix ceramic laminate veneers was (6.13±1.27) μm and (6.84±2.19) μm, respectively, without a statistically significant difference (P>0.05). The marginal roughness of the glass-matrix ceramic laminate veneers was higher than that of the resin-matrix ceramic laminate veneers with a statistically significant difference (P < 0.001). The marginal fitness of 0.3 mm and 0.5 mm glass-matrix ceramic laminate veneers were (66.30±26.71) μm and (85.48±30.44) μm, respectively. The marginal fitness of 0.3 mm and 0.5 mm resin-matrix ceramic laminate veneers were (56.42±19.27) μm and (58.36±8.33) μm, respectively. There was no statistically significant difference among the 4 groups (P>0.05). For glass-matrix ceramics, the flexural strength was (327.40±54.25) MPa, the flexural modulus was (44.40±4.39) GPa, and the modulus of resilience was (1.24±0.37) MPa. For resin-matrix ceramics, the flexural strength was (173.71±16.61) MPa, the flexural modulus was (11.88±0.51) GPa, and the modulus of resilience was (1.29±0.27) MPa. The flexural strength and modulus of glass-matrix ceramics were significantly higher than those of resin-matrix ceramics (P < 0.001), but there was no statistically significant difference in the modulus of resilience between the two materials (P>0.05).@*CONCLUSION@#The marginal roughness of CAD/CAM glass-matrix ceramic laminate veneers is greater than that of resin-matrix ceramic laminate veneers, but there was no statistically significant difference in marginal fitness among them. Increasing the thickness can reduce the marginal roughness of glass-matrix ceramic laminate veneers, but has no effect on the marginal roughness of resin-matrix ceramic laminate veneers.


Subject(s)
Ceramics , Computer-Aided Design , Dental Porcelain , Dental Veneers , Materials Testing , Surface Properties
10.
Journal of Peking University(Health Sciences) ; (6): 95-99, 2022.
Article in Chinese | WPRIM | ID: wpr-936118

ABSTRACT

OBJECTIVE@#To compare the effects of resin base and different retention depth on the fracture resistance of mandibular molars restored with nano-ceramic endocrowns.@*METHODS@#Forty mandibular molars selected and randomly divided into 5 groups: ① The control group which was consisted of intact teeth, ② the non-resin base group, ③ the 2 mm retention depth group, ④ the 3 mm retention depth group, ⑤ the 4 mm retention depth group, respectively. After tooth preparation, in vitro root canal therapy was conducted, which was followed by endocrown design, production and adhesive of groups ②-⑤. All the samples were under load (N) of the universal mechanical testing machine after embedding. The fracture pattern of each sample was observed under stereomicroscope. Then the microstructure of the fracture surface was observed by scanning electron microscopy.@*RESULTS@#The fracture loads of each group were respectively: the control group fracture load was (3 069.34±939.50) N; experimental groups: fracture load of (2 438.04±774.40) N for the group without resin base; fracture load of (3 537.18±763.65) N for the group with 2 mm retention depth. The fracture load of the retention depth 3 mm group was (2 331.55±766.39) N; the fracture load of the retention depth 4 mm group was (2 786.98±709.24) N. There was statistical significance in the effect of resin base and different retention depth on the fracture loads of molars restored with nano-ceramic endocrown (P < 0.05). Repairable fractures in each group were as follows: control group 2/8, non-resin base group 1/8, retention depth of 2 mm group 1/8, retention depth of 3 mm group 2/8, and retention depth of 4 mm group 0/8. The effects of the retention depth and the presence of resin base on the fracture resistance of the resin nano-ceramic endocrowns were statistically significant (P < 0.05). Scanning electron microscopy showed more arrest lines and small twist hackles on the fracture surface of the restorations with resin base (retention depths of 2 mm, 3 mm, and 4 mm), with cracks extending towards the root. In addition to the characteristics above, more transverse cracks parallel to the occlusal surface, pointing outwards from the center of the pulp cavity retention, were also observed on the fracture surface of the non-resin base restorations.@*CONCLUSION@#When molar teeth with nano-ceramic endocrowns are restored, resin base and the retention depth of 2 mm help the teeth to obtain optimal fracture strength.


Subject(s)
Ceramics , Composite Resins , Dental Porcelain , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Molar
12.
Braz. dent. j ; 32(3): 56-64, May-June 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345501

ABSTRACT

Abstract It aims on evaluate the effect of the test environment on static fatigue behavior of lithium disilicate-based (LD), and yttrium oxide-stabilized zirconia (YSZ) ceramics. Specimens of LD (IPS e.max CAD, Ivoclar Vivadent) and YSZ (IPS e.max ZirCAD MO, 3 mol% Y2O3, Ivoclar Vivadent) were randomly allocated into three groups: tested in air, inert (paraffin oil, Sigma Aldrich) or distilled water. The static fatigue test (n=15) was performed using a piston-on-three ball assembly, adapted from ISO 6872, as follows: starting load 100 N for LD and 300 N for YSZ; loading application time set to 1 hour for each loading step; step size of 50 N for LD and 100 N for YSZ, applied successively until fracture. Data from static fatigue strength (MPa) and time to fracture (hours) were recorded. Fractographic analysis was executed. Survival analysis corroborates absence of influence of environment on static fatigue outcomes (fatigue strength, time to fracture and survival rates) for YSZ. For LD, specimens tested in air presented statistically superior survival rate and static fatigue strength (p= 0.025). In regards of time to fracture, LD tested in air were superior than when tested in distilled water (p=0.019) or inert (p=0.017) environments. No statistical differences for Weibull modulus were observed. Failures started on the tensile stress surface. Thus, the test environment did not affect slow crack growth (SCG) mechanisms during static fatigue test of YSZ ceramics, but it plays a significant role for the static fatigue behavior of lithium disilicate-based glass ceramics, indicating a high susceptibility to SCG.


Resumo O presente estudo objetivou investigar a influência do ambiente de teste no comportamento a fadiga estática (resistência à fratura e tempo para falha) de cerâmicas à base de dissilicato de lítio (LD) e zircônia estabilizada com ítria (YSZ). Espécimes de LD (IPS e.max CAD, Ivoclar Vivadent) e YSZ (IPS e.max ZirCAD MO, 3mol% Y2O3, Ivoclar Vivadent) foram obtidos e alocados aleatoriamente em três grupos: testado em ar, em líquido inerte (óleo de parafina) ou em água destilada. O teste de fadiga estática (n= 15) foi realizado usando o teste pistão sobre três esferas, ISO 6872, da seguinte forma: carga inicial 100 N para LD e 300 N para YSZ; tempo de aplicação de carregamento definido para 1 hora para cada etapa de carregamento; tamanho do passo de 50 N para LD e 100 N para YSZ, aplicados sucessivamente até a fratura. Dados de resistência à fadiga estática (MPa) e tempo até a fratura (horas) foram registrados. A análise fractográfica foi executada. A análise de sobrevivência corrobora a ausência de influência do ambiente de teste nos resultados de fadiga estática (resistência à fadiga, tempo de fratura e taxas de sobrevivência) para a YSZ. Para LD, os corpos de prova testados em ar apresentaram taxa de sobrevivência e resistência à fadiga estática estatisticamente superiores (p= 0,025). Em relação ao tempo de fratura, os espécimes LD testados em ar foram superiores aos testados em água destilada (p= 0,019) ou em ambiente inerte (p= 0,017). Não foram observadas diferenças estatísticas para o módulo de Weibull. Todas as falhas começaram no lado onde se concentra a tensão de tração (lado de baixo) durante o teste. Com base nisso, observa-se que o ambiente de teste não afetou os mecanismos de crescimento lento de trinca durante o teste de fadiga estática da cerâmica YSZ, mas desempenha um papel significativo na resistência à fadiga estática da cerâmica de vidro à base de dissilicato de lítio, indicando alta susceptibilidade ao crescimento lento e subcrítico de trincas.


Subject(s)
Ceramics , Dental Porcelain , Surface Properties , Zirconium , Materials Testing , Computer-Aided Design , Dental Stress Analysis , Glass
13.
Braz. dent. j ; 32(3): 44-55, May-June 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345505

ABSTRACT

Abstract In the RLT (Rapid Layer Technology), veneering ceramic and framework are fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) and then cemented to obtain the restoration. This study aimed to evaluate the effect of the thickness of veneering ceramic manufactured by the RLT technique on the fracture resistance (FR) of bilayer crowns with zirconia frameworks. Twenty zirconia frameworks and twenty feldspathic posterior crowns with two different veneering ceramic occlusal thicknesses (1mm=TF1; 2mm=TF2) were manufactured using CAD/CAM system. The specimens were luted to an epoxy resin abutment with resin cement and mechanically cycled (200N and 4.5×105 Pa, 37°C, 2×106 cycles, 3Hz). The FR test was performed (10kN, 0.5mm/min), and the specimens were analyzed in a stereomicroscope. For the stress analysis (finite element analysis, FEA), a 10kN load was equal to the in vitro test, and the principal stress was evaluated. The FR data were analyzed by Student's t-test and Weibull's analysis. The thickness influenced the FR of bilayer crowns. The FR was higher in the TF2 than in the TF1 group. The TF2 group presented the highest characteristic strength compared to the group TF1. The predominant type of failure was delamination. The FEA showed higher stress concentrations below the loading application point at the veneering cement interface in the 1-mm-thick model. The bilayer crowns manufactured using the approach of 2mm of veneering ceramic promoted higher FR compared to the group with 1mm veneering ceramic. Also, the FEA showed that the veneer ceramic thickness has an effect on stress distribution in zirconia-based bilayer crowns.


Resumo Na RLT (Rapid Layer Technology), a cerâmica de cobertura e infraestrutura são fabricados pelo Computer-Aided Design / Computer-Aided Manufacturing (CAD / CAM) e cimentados para obter a restauração. Este estudo teve como objetivo avaliar o efeito da espessura da cerâmica de cobertura fabricada pela técnica RLT na resistência à fratura (RF) de coroas bilaminadas com infraestrutura de zircônia. Vinte infraestruturas de zircônia e vinte coroas posteriores feldspáticas com duas espessuras oclusais da cerâmica de cobertura (1mm = TF1; 2mm = TF2) foram fabricadas usando o sistema CAD / CAM. Os espécimes foram cimentados em preparos de resina epóxi com cimento resinoso dual e ciclados mecanicamente (200N e 4,5×105 Pa, 37° C, 2×106 ciclos, 3Hz). O teste de RF foi realizado (10kN, 0,5mm / min) e, posteriormente, os espécimes foram analisados em estereomicroscópio. Para a análise de tensão (análise de elementos finitos, FEA), uma carga de 10kN foi aplicada igual ao teste in vitro, e a tensão principal foi avaliada. Os dados de RF foram analisados pelo teste t de Student e análise de Weibull. A espessura mostrou forte influência na RF das coroas bilaminadas. A RF foi maior em TF2 do que no grupo TF1. O grupo TF2 apresentou a maior resistência característica em relação ao grupo TF1. O tipo de falha predominante foi a delaminação. O FEA mostrou maiores concentrações de tensões abaixo do ponto de aplicação da carga, na interface cimento e cerâmica de cobertura no modelo de coroa de 1 mm de espessura. As coroas de bilaminadas confeccionadas com 2 mm de cerâmica de cobertura promoveram maior RF em comparação ao grupo com cerâmica de cobertura de 1 mm. Além disso, a FEA mostrou que a espessura da cerâmica de cobertura tem um efeito na distribuição de tensões em coroas bilaminadas à base de zircônia.


Subject(s)
Humans , Dental Porcelain , Dental Veneers , Technology , Zirconium , Materials Testing , Ceramics , Computer-Aided Design , Dental Restoration Failure , Crowns , Dental Stress Analysis
14.
Braz. dent. j ; 32(2): 53-63, Mar.-Apr. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1339327

ABSTRACT

Abstract The present study was a prospective, controlled, randomized, clinical short-term trial aiming to evaluate the clinical performance of adhesively luted, lithium disilicate and feldspathic glass-ceramics onlays over a period up to 2 years. A total of 11 patients (7 female, 4 male; age range: 18-60 years, mean age: 39 years) were selected for this study. Each patient received a maximum of two restorations per group in a split-mouth-design. LD: Eleven onlays, performed with lithium disilicate-based ceramic (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein), and FP: Eleven onlays, performed with feldspathic ceramic (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Recalls were performed at 2 weeks (baseline = R1), 1 year (R2) and 2 years (R3) after the cementation by three calibrated blinded independent investigators using mirrors, magnifying eyeglasses, probes and bitewing radiographs. The postoperative sensitivity, secondary caries, marginal integrity, marginal discoloration, color match, surface roughness, tooth integrity, and restoration integrity were evaluated. The Friedman test was used to determine if there was a statistically significant difference in time-to-time comparison of the parameters in the ceramics restorations. A total of 95.4% of the restorations were clinically acceptable at the 2-year recall, without a difference for any evaluation parameter for both ceramic materials. Based on the 2-year data, the CAD-CAM onlays manufactured with feldspathic and lithium-disilicate based ceramics showed similar clinical performance.


Resumo O presente estudo é um estudo clínico prospectivo, controlado, randomizado e de longo curto prazo, com o objetivo de avaliar o desempenho clínico de restauraç ões adesivas cerâmica vítrea reforçada com dissilicato de lítio e cerâmica feldspática por um período de até 2 anos. Um total de 11 pacientes (7 mulheres, 4 homens; faixa etária: 18-60 anos, idade média: 39 anos) foram inseridas para este estudo. Cada paciente recebeu duas restaurações por grupo em um delineamento de boca dividida. LD: Onze onlays, realizados com cerâmica à base de dissilicato de lítio (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein); e FP: Onze onlays, realizados com cerâmica feldspática (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Os retornos foram realizados em 2 semanas (linha de base = R1), 1 ano (R2) e 2 anos (R3) após a cimentação, por três investigadores independentes, cegos e calibrados, usando espelhos, óculos de aumento, sondas e radiografias interproximais. Foram avaliadas a sensibilidade pós-operatória, cárie secundária, integridade marginal, descoloração marginal, correspondência de cores, rugosidade da superfície, integridade dentária e integridade da restauração. O teste de Friedman (95%) foi utilizado para determinar se havia uma diferença estatisticamente significante na comparação periódica dos parâmetros nas restaurações cerâmicas. Um total de 95,4% das restaurações estava clinicamente aceitável no retorno de 2 anos, sem diferença para qualquer parâmetro de avaliação para ambos os materiais cerâmicos. Com base nos dados de 2 anos, as restaurações CAD-CAM fabricados com cerâmica feldspática e à base de dissilicato de lítio apresentaram desempenho clínico semelhante.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Inlays , Mouth , Prospective Studies , Dental Porcelain
15.
Rev. habanera cienc. méd ; 20(1): e3115, ene.-feb. 2021. graf
Article in Spanish | LILACS, CUMED | ID: biblio-1156686

ABSTRACT

Introducción: Combinar tratamientos regenerativos con injertos de tejido blando impide que el tejido periimplantario se atrofie y altere la estética. Los resultados de esta combinación son discutidos en la literatura actual cuando se trata de implantes inmediatos. Objetivo: Describir el tratamiento regenerativo combinando plasma rico en fibrina e injerto conectivo en la instalación de un implante dental en el sector anterosuperior. Presentación del caso: El paciente fue un varón de 40 años de edad sin antecedentes de enfermedades sistémicas, con trauma facial. Al examen clínico se observó una corona de porcelana fracturada a nivel cervical vestibular, secreción purulenta en proceso de cicatrización y contorno gingival alterado. En el examen radiográfico se evidenció una lesión periapical con aparente reabsorción radicular. Se extrajo el diente, se colocó plasma rico en fibrina para mejorar la cicatrización, se esperaron 6 semanas y se colocó un implante. Al cabo de 4 meses se realizó la segunda fase con un injerto de tejido conectivo y colocación del cicatrizal, se esperaron dos semanas y se colocó una corona de porcelana. Conclusiones: En el presente caso, la combinación de plasma rico en fibrina e injerto conectivo favoreció el aspecto estético periimplantario sin evidenciarse complicaciones durante el posoperatorio(AU)


Introduction: Combining regenerative treatments with soft tissue grafts prevents atrophy of the peri-implant tissue and alterations in esthetics. The results of this combination are discussed in the current literature. Objective: To describe the regenerative treatment, combining Fibrin-rich plasma and connective tissue graft in the installation of a dental implant in the upper anterior sector. Case presentation: Forty-year-old male patient with facial trauma. He has no history of systemic diseases. On clinical examination, a fractured porcelain crown was found at the vestibular cervical level. There was purulent discharge in the healing process and altered gingival contour. Radiographic examination revealed a periapical lesion with apparent root resorption. The tooth was extracted; fibrin-rich plasma was placed to improve healing. Six weeks after, an implant was placed. After the first four months, the second phase was performed with a connective tissue graft and placement of the scar tissue; two weeks after, a porcelain crown was placed. Conclusions: In the present case, the combination of Fibrin-rich plasma and connective tissue graft favored the peri-implant esthetic appearance without evidence of complications during the postoperative period(AU)


Subject(s)
Humans , Male , Adult , Root Resorption , Dental Implants/standards , Dental Porcelain , Postoperative Period , Platelet-Rich Fibrin/physiology
16.
Journal of Peking University(Health Sciences) ; (6): 402-405, 2021.
Article in Chinese | WPRIM | ID: wpr-942194

ABSTRACT

OBJECTIVE@#To evaluate the effects of different edge compensation angles on the fracture strength of multilayer zirconia all-ceramic crowns and traditional uniform zirconia all-ceramic crowns.@*METHODS@#The resin tooth preparation specimen of the mandibular first molar with a knife-edge was fabricated. A 3D digital model of the specimen was obtained by scanning it with a 3D dental model scanner. The 3D digital model was imported into computer aided design (CAD) software, and three 3D digital models of the full crown with the same surface shape are designed with the edge compensation angles of 30°, 45° and 60°, respectively. Then, the designed 3D digital model is imported into computer aided manufacturing (CAM) software. Three kinds of multilayer and homogeneous zirconia all-porcelain crowns with different edge compensation angles were fabricated, 10 each for a total of 60. The fracture load of each crown was measured under the electronic universal testing machine.@*RESULTS@#Fracture load of multilayer and uniform zirconia all-ceramic crowns, (4 322.86±610.07) N and (5 914.12±596.80) N in the 30° group, (5 264.82±883.76) N and (5 220.83±563.38) N in the 45° group and (4 900.42±345.41) N and (5 050.22±560.24) N in the 60° group, respectively. The fracture load of multi-layer zirconia all-ceramic crowns in the 30° group was significantly lower than that of homogeneous zirconia all-ceramic crowns(P < 0.05); there was no statistical significance in 45° group and 60° group(P>0.05). In the multi-layer zirconia all-ceramic crowns: the fracture load of the 30° group was significantly lower than that of the 45° group (P < 0.05); there was no significant difference between the 30° group and the 60° group, the 45° group and the 60° group (P>0.05).In uniform zirconia full crown group: the 30° group was higher than the 45° group, the 30° group was higher than the 60° group (P < 0.05), and there was no significant difference between the 45° group and the 60° group (P>0.05).@*CONCLUSION@#The fracture loads of three kinds of uniform and multilayer zirconia all ceramic crowns with different edge compensation angles can meet the clinical requirements. A smaller edge compensation angle is recommended when using traditional zirconia all-ceramic crowns, while 45° is recommended when using multi-layer zirconia all-ceramic crowns.


Subject(s)
Ceramics , Computer-Aided Design , Crowns , Dental Porcelain , Dental Prosthesis Design , Dental Restoration Failure , Dental Stress Analysis , Flexural Strength , Materials Testing , Zirconium
17.
São José dos Campos; s.n; 2021. 75 p. ilus, graf, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1362274

ABSTRACT

Este estudo avaliou a resistência à fadiga cíclica de estruturas em forma de disco cerâmico multicamada de configuração tradicional (T) e bionispirado em macroescala (B), cimentadas de forma adesiva ao substrato analógo à dentina. As amostras foram produzidas com zircônia (Ø = 10 mm, espessura = 0,5 mm) e cerâmica feldspática (Ø = 10 mm, espessura = 1,5 mm) e foram unidas com três técnicas diferentes (n = 15): Injeção (inj); com vidro de fusão Crystal Connect (cv) e técnica cimentada (cim). Para a configuração tradicional a zircônia foi a infraestrura sobre qual a cerâmica feldspática foi aderida. Para os bioinspirados, a zircônia foi a supraestrutura e a cerâmica feldspática foi a infraestrutura. Os discos foram cimentados em resina G-10 (Ø = 10 mm, espessura = 1,5 mm). As amostras foram testadas sob a abordagem de fadiga cíclica até apresentar alguma trinca observada por transluminação. O método stepwise: 20 Hz, seguidos por etapas incrementais de 200 N a cada 10 x 103ciclos, com carga inicial de 600 N até 2600 N com pistão de 40 mm de diâmetro e célula de carga de 5 KN (Instron Electropuls E 3000, Instron, Glenview, IL, EUA). Todas as amostras foram analisadas estereomicroscópio para determinar o tipo de falha e uma amostra representativa de cada grupo foi analisada no microscópio eletrônico de varredura (MEV). As configurações bioinspiradas testadas foram estatisticamente semelhantes (p > 0,05) e não aumentaram a sobrevivência à fadiga das estruturas comparadas com a técnica tradicional. A bioinspiração apresentou predominantemente trincas radias e únicas. A gradação do modulo elástico em macroescala e a configuração das estruturas. A utilização do conector vítreo se mostro favorável para diminuir das trincas no material análogo á dentina.


This study evaluated the cyclic fatigue resistance of multilayer ceramic discshaped structures of traditional configuration (T) and macroscale bionispirate (B), cemented adhesively to the substrate analogic to dentin. The samples were produced with zirconia (Ø = 10 mm, thickness = 0.5 mm) and feldspar ceramics (Ø = 10 mm, thickness = 1.5 mm) and were joined with three different techniques (n = 15): Injection (inj); with Crystal Connect melting glass (cv) and cemented technique (Cim). For the traditional configuration zirconia was the infraestrura on which the feldspathic ceramic was adhered. For the bioinspired, zirconia was the superstructure, and feldspathic ceramics was the infrastructure. The discs were cemented in G-10 resin (Ø = 10 mm, thickness = 1.5 mm). The samples were tested under the cyclic fatigue approach until some crack was observed by translumination. The stepwise method: 20 Hz, followed by incremental steps of 200 N every 10 x 103 cycles, with initial charge from 600 N to 2600 N (40 mm diameter piston) and 5 KN load cell (Instron Electropuls E 3000, Instron, Glenview, IL, USA). All samples were analyzed stereomicroscopically to determine the type of failure and a representative sample of each group was analyzed in the scanning electron microscope (SEM). The bioinspired configurations tested were statistically similar (p > 0.05) and did not increase the fatigue survival of the structures compared to the traditional technique. The bioinspiration presented predominantly radial and unique cracks. The use of the vitreous connector was favorable to decrease the cracks in the analogous dentin material.


Subject(s)
Zirconium/chemistry , Dental Prosthesis , Dental Porcelain , Materials Testing , Microscopy, Electron, Scanning , Survival Analysis , Shear Strength
18.
Araçatuba; s.n; 2021. 78 p. tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1510394

ABSTRACT

O objetivo deste estudo foi avaliar a influência do material cerâmico, cimento e tipo de substrato na qualidade estética de restaurações indiretas. A pesquisa científica foi dividida em duas partes. Na primeira análise, a alteração de cor e luminosidade de restaurações cerâmicas à base de dissilicato de lítio (e.max CAD), monossilicato de lítio (Celtra Duo) e cerâmica híbrida (Vita-Enamic CAD) foram analisadas quando sobrepostas em diferentes substratos (esmalte bovino, metal e zircônia), após a aplicação de pastas de prova "try-in" e após a cimentação com diferentes tipos de cimentos resinosos (RelyX Veneer, Variolink Esthetic LC e RelyX Ultimate). As análises foram realizadas em espectrofotômetro de reflexão UVVisivel (n=6). Os resultados mostraram que o tipo de substrato influenciou de maneira mais significante a estabilidade de cor e luminosidade das cerâmicas, independente da cor e tipo de material de cimentação. No segundo projeto, o objetivo foi avaliar a alteração cromática e a transmitância de diferentes restauraçoes cerâmicas: dissilicato de lítio (e.max CAD), monossilicato de lítio (Celtra Duo) e cerâmica híbrida (Vita-Enamic CAD) em oito diferentes espessuras (0,3mm à 2,0mm), com variação da potência do fotopolimerizador (1000mW/cm2 e 3200mW/cm2 ) e submetidos ao envelhecimento UV. As análises da alteração cromática foram realizadas em espectrofotômetro de reflexão UV-Visivel (n=8), enquanto que a análise da transmitância das cerâmicas foi realizada medindo-se a radiação de luz transmitida pelos diferentes materiais com um medidor de potência. Os resultados obtidos mostraram que os materiais cerâmicos estudados apresentam comportamentos diferentes quanto a estabilidade de cor das peças cimentadas. As diferentes espessuras influenciaram na cor do conjunto após o envelhecimento UV em todos os materiais estudados, sendo que a cerâmica de dissilicato de lítio e a cerâmica híbrida apresentaram influência nas espessuras mais delgadas. A transmitância dos materiais foi influenciada pela sua espessura e composição. A variação da potência do fotopolimerizador não influenciou na estabilidade de cor de todos os materiais analisados nas diferentes espessuras(AU)


The aim of this study was to evaluate the influence of ceramic material, resin cement and type of substrate in the aesthetic quality of indirect restorations. The research was divided into two chapters. In the first analysis, the color difference and luminosity of lithium disilicate (e.max CAD), zirconia-reinforced lithium silicate (Celtra Duo) and polymer infiltrated ceramic network (Vita Enamic CAD) were analyzed on different substrates (bovine enamel, metal and zirconia), after try-in pastes placed between the ceramics and substrates and after luting with different resin cements (RelyX Veneer, Variolink Esthetic LC e RelyX Ultimate) (n=6). The results showed that the type of substrate had more influence on the color stability and luminosity of ceramics, independent of the color and resin cement used. In the second study, the aim was to evaluate the color difference and transmittance of different ceramic restorations: lithium disilicate (e.max CAD), zirconia-reinforced lithium silicate (Celtra Duo) and polymer infiltrated ceramic network (Vita Enamic CAD) in eight thickness (0.3mm to 2.0mm), using light-emitting diode Valo Cordless (Standard and Xtra power modes) submitted to UV aging (n=8). The transmittance was done measuring the light transmitted through the materials with a power meter. The results showed that the ceramic materials showed different behavior in the color stability, especially for the thinner lithium disilicate and polymer infiltrated ceramic network materials. The transmittance was influenced by the thickness and composition of the materials. The variation in the power intensity of the lightemitting diode did not influence the color stability of the materials, independent of its thickness(AU)


Subject(s)
Color , Dental Porcelain , Dental Restoration, Permanent , Esthetics, Dental , Polymerization
19.
Braz. dent. sci ; 24(3): 1-11, 2021. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1281761

ABSTRACT

Objective: To evaluate the clinical behavior of milled BioHPP PEEK copings veneered with Visio.lign composite resin in comparison with metal copings veneered with feldspathic porcelain as single posterior crowns. Material and Methods: Twenty Four full coverage posterior crowns were fabricated for endodontically treated molars divided into 2 groups according to the material used. Twelve milled BioHPP PEEK-based crowns (Group 1) and Twelve Porcelain Fused to Metal (PFM) crowns (Group 2). The preparations were standardized with an equi-gingival, deep chamfer finish line for all teeth. BioHPP PEEK and metal copings were fabricated by CAD/CAM technology and lost wax technique respectively. These coping were veneered according to manufactures instructions either by special composite resin or low fusing glass ceramic respectively. The restorations were cemented then clinical evaluation of these crowns was assessed regarding mechanical failure, marginal integrity and patient satisfaction every two months for one year. Results: Although two PEEK crowns were fractured, both PEEK and PFM crowns showed similar fracture (mechanical failure) and marginal integrity without significant difference (p > 0.05). BioHPP PEEK-based crowns showed statistically significantly lower patient satisfaction than PFM crowns after six months (p-value = 0.013, Effect size = 1.157) but all the patients were generally satisfied. Conclusion: BioHPP PEEK-based crowns showed clinically similar and accepted mechanical behavior and marginal integrity but less patient's satisfaction than PFM crowns after six months. So BioHPP PEEK-based crowns may be used as an alternative tooth-colored metal-free fixed restoration for one year (AU)


Objetivo: Avaliar o comportamento clínico de copings fresados de BioHPP PEEK com cobertura de resina composta Visio.lign em comparação com copings metálicos cobertos com cerâmica feldspática em coroas unitárias posteriores. Material e Métodos: Vinte e quatro coroas totais posteriores de foram confeccionadas para molares tratados endodonticamente e divididos em 2 grupos de acordo com o material utilizado. Doze coroas fresadas à base de BioHPP PEEK (Grupo 1) e doze coroas de porcelana fundida ao metal (PFM) (Grupo 2). Os preparos foram padronizados para todos os dentes com término de chanfro largo ao nível gengival. BioHPP PEEK e os copings metálicos foram fabricados por tecnologia CAD/CAM e técnica da cera perdida, respectivamente. A aplicação da cobertura sobre os copings foi realizada de acordo com as instruções do fabricante, por resina composta especial ou cerâmica vítrea de baixa fusão, respectivamente. As restaurações foram cimentadas e a avaliação clínica dessas coroas foi realizada quanto à falha mecânica, integridade marginal e satisfação do paciente a cada dois meses durante um ano. Resultados: Embora duas coroas de PEEK tenham sido fraturadas, ambas as coroas de PEEK e PFM apresentaram fraturas semelhantes (falha mecânica) e integridade marginal sem diferença significativa (p > 0,05). As coroas à base de BioHPP PEEK mostraram uma satisfação do paciente significativamente menor do que as coroas PFM após seis meses (valor de p = 0,013; tamanho do efeito = 1,157), mas todos os pacientes estavam geralmente satisfeitos. Conclusão: As coroas à base de BioHPP PEEK, em comparação às coroas PFM, mostraram desempenho clínico similar, aceitável comportamento mecânico e integridade marginal, mas menos satisfação do paciente, após seis meses. Portanto, as coroas à base de BioHPP PEEK podem ser utilizadas como uma alternativa de restauração livre de metal semelhante à cor do dente, por um ano. (AU)


Subject(s)
Patient Satisfaction , Metal Ceramic Alloys , Dental Porcelain
20.
West China Journal of Stomatology ; (6): 341-346, 2021.
Article in English | WPRIM | ID: wpr-878453

ABSTRACT

OBJECTIVES@#To analyze the chromatic properties and translucency of porcelain veneers made from different ceramic materials against the background of tetracycline-stained teeth.@*METHODS@#Porcelain specimens (A1, A3, B2, B4) measuring 0.50 mm in thickness were prepared by heat-press casting and layering. The L*, a*, and b* values of the specimens against simulated tetracycline tooth and black-and-white backgrounds were measured by a spectrophotometer, and color differences ΔE@*RESULTS@#The ΔE@*CONCLUSIONS@#When changing the color of tetracycline-stained teeth, 0.50 mm-thick IPS d.SIGN feldspathic veneers with an opaque layer provide better chromatic properties than IPS e.max Press LT glass ceramic veneers. However, the translucency of feldspathic veneers is generally poorer than that of glass ceramic veneers.


Subject(s)
Ceramics , Color , Dental Porcelain , Dental Veneers , Materials Testing , Tetracyclines
SELECTION OF CITATIONS
SEARCH DETAIL